1
Hold or suspend the full bailer vertically and
slowly insert the VOC Removal Device into the bottom valve until
the sample begins to flow from the discharge tube;
|
|
2
Lift a clean VOA vial around the discharge tube;
|
|
3
Hold the vial in that position and count the
seconds until it starts to overflow;
4
Continue to hold the vial in that position, with
the sample overflowing, for an equal number of seconds to obtain
one full, unagitated sample volume.1
|
|
5
Slowly withdraw the vial from around the discharge
tube taking care to maintain the convex meniscus (A) on the sample
in the vial;
|
|
6
Close the vial with the Teflon lined screw cap and
screw the cap on tightly;
|
|
7
Invert the vial and rap it sharply several times
against your knuckles to check for entrapped air.
Reject
any vials containing air bubbles; protect all vials containing
sample from bright light; ice samples at once.
|